Nuform Building Technologies Inc.

Toll Free - 1.877.747.9255

Get a Quote Now!
   
 
 

CODE EVALUATION

   

 

   

NUFORM™ is pleased to provide the following US and Canadian code evaluations for your information.

 

Canada

CONFORM™ Code Compliance - National Building Code of Canada, 2005

Code compliance for CF4, CF6, CF8 and CF8i permanent formwork
Code articles applicable to Interior Finish, Non-Combustible Construction, Fire Resistance Rating,
Exterior Finish and Structural Requirements
Test results, consultant reviews and references, for applicable code articles
Use for bearing and non-bearing walls 
Permitted in non-combustible construction
Flame spread not more than 25
Exterior finish meets ULC S134
Two hour fire resistance rating (CF6, CF8 and CF8i) 

 Code Compliance - NBC (PDF 70KB)

 

Ontario

CONFORM™ Code Compliance - Ontario Building Code, 2006

Code compliance for CF4, CF6, CF8 and CF8i permanent formwork
Code articles applicable to Interior Finish, Non-Combustible Construction, Fire Resistance Rating,
Exterior Finish and Structural Requirements
Test results, consultant reviews and references, for applicable code articles
Use for bearing and non-bearing walls
Permitted in non-combustible construction
Flame spread not more than 25
Exterior finish meets ULC S134
Two hour fire resistance rating (CF6, CF8 and CF8i)

 Code Compliance - OBC (PDF 70KB)

United States

CONFORM™ - ICC-ES Evaluation

Evaluation Report ESR-1223
Section: 03130 - Permanent Forms
Issued September 1, 2006: Re-Issued October 1, 2008
Compliance with 2006 International Building Code ® (IBC)
Compliance with 2006 International Residential Code ® (IRC)
CF4, CF6, CF8 and CF8i Permanent Formwork
For bearing and non-bearing walls in Types I, II, III and V construction
Interior finish meets Class A rating
Exterior finish permits fire separation distance of 5 feet or less
Two hour fire resistance rating (CF6, CF8 and CF8i)

ICC-ES Evaluation ESR-1223 (PDF 345KB)

Florida

CONFORM™ - FBC Product Approval

Florida Product Approval # FL7382
Structural Components - Finished Forms
Issued December 6, 2006
Compliance with Florida Building Code (FBC) 2004
Finished polymer form for cast-in-place concrete walls. A stay-in-place form for 4", 6" or 8" thick plain or reinforced concrete walls for residential and commercial construction. Design and use to be in accordance with ICC ESR-1223 Evaluation Report. Not to be used in HVHZ.

Florida Product Approval # - FL7382 (PDF 119KB) 

PAST CODE EVALUATIONS

Canada

CONFORM™ - CCMC Evaluation

Evaluation Report 12536-R
Issued September 10, 1993: Re-evaluated May 30, 2005
Compliance with Part 9 – National Building Code of Canada (NBC) 1995 - Housing and Small Buildings
Single family dwellings
One and two storey, including foundation walls
CF walls, roofs and floors

Ontario

CONFORM™ - OBC Minister’s Ruling

Minister's Ruling 95-01-20-(12536-R)
Issued January 29, 1995: Revised March 24, 2000
Compliance with Part 9 – Ontario Building Code (OBC) 1997 - Housing and Small Buildings
Approval of CCMC 12536-R for Province of Ontario

Since 1992, testing and research programs have indicated compliance to numerous building codes around the world, including, China, Japan, Argentina, India, Europe and Russia. Testing has been conducted for hurricane criteria, seismic effects, and blast mitigation. In addition, testing and research has been conducted on many aspects that are not directly referenced in the building codes. Please contact our office should you require technical information on a specific aspect of our product.

The following documentation is provided for download in PDF format. You will need Adobe Acrobat Reader to view or print. Download Adobe Acrobat Reader.

FEATURED PRODUCTS
 
   
POPULAR DOWNLOADS
 
 
 
  © 2010 Nuform Building Technologies Inc. | Privacy Policy